Install at the perfect height.
Baby changing station height ada.
8365328 8276229 d605886 d601843 canadian patent no.
Oval baby changing stations.
Baby changing stations.
Baby changing stations types.
Baby changing stations should meet the requirements of the ada.
Ada regulations also state that baby changing stations must be located in an area that is easily accessible and free from obstructions.
They have to be mounted so that the very top of the changing table surface when it is opened cannot be any higher than 34 inches off the floor she says.
Information and figures are taken directly from the 2010 ada standards for accessible design regulation www ada gov and can be freely viewed or downloaded at your convenience.
Forward reach a unit should not require a high forward reach no more than 48 inches and a low reach of 15 inches above the finish floor or ground when unobstructed.
This is required so patrons using wheelchairs can easily access the unit as well as open and close the changing station.
Recess mounted plastic baby changing station with stainless steel flange is a stylish and safe option for restroom facilities.
This baby changing station has been tested to support 200 lbs with minimal deflection.
Side reach like forward reach requirements side reach compliance calls for a high side reach of 48 inches and a low side reach of 15 inches.
There are specific mounting heights and other requirements of baby changing stations in restrooms says ada compliance expert joan stein of stein consulting inc pittsburgh.
Any change to restroom functionality inevitably turns to the question of americans with disabilities act ada compliance.
The ada americans with disabilities act has set requirements for baby changing stations.
Recess mounted stainless steel clad baby changing station is the premier choice for upscale restroom facilities.
Listed below are standards for baby changing stations.
This product is designed for infants only up to 3 5 years of age and weighing less than 50 lbs.
Toe clearance at least 9 inches 230mm above the finish floor must be provided for the full depth.
130179 european community 1114367 0001 1114367 0002 australia patent no.
Check your local code for addition information and requirements.
The ada mandates that baby changing stations be present in both men s and women s restrooms and must be placed at a height of 27 inches from the floor.
Below is a diagram from diaper depot about mounting baby changing stations.
For horizontal changing stations the ada requires that the unit protrude no more than 4 from the wall and be no higher than 27 inches from the floor.
The ada standards are issued by the department of justice doj and the department of transportation dot.
The americans with disabilities act ada was created to ensure access to buildings and structures for people with disabilities.